4–13
Adjustment Procedures
9. Repeat steps 6 through 8 at the right end of the hammer bank.
10. After adjusting both sides, check the gap again at both ends. Readjust if
necessary.
11. When the platen gap is correct at both ends of the platen, adjust the
platen open belt (page 4–6).
12. Install the shuttle cover assembly (page 5–16).
13. Check the hammer phasing adjustment (page 4–25).
14. Return the printer to normal operation (page 4–3).
1. Forms Thickness Lever
2. Feeler Gauge (0.011 inch or 0.28 mm)
3. Hammer Bank Cover Plate
4. Ribbon Mask
5. Set Screw, 3/32 inch hex (2)
1
3
4
2
NOTE: Left side adjustment
shown. Right side is
the same.
5
Figure 4–5. Platen Gap Adjustment